°Ç¹°¼Ò°³-±¹¿Ü -»ó¾÷¿ë |
À§Ä¡ : Stockport / England
Project Data
Building |
|
¿ëÀû |
7,100 §© |
¹Ù´Ú¸éÀû |
2,087 §³ |
ÁöºØ¸éÀû |
1,316 §³ |
¿Üº®¸éÀû |
800 §³ |
â¸éÀû : Àüü |
325 §³ |
³²ÂÊ |
235 §³ |
Atrium |
|
¿ëÀû |
410 §© |
¹Ù´Ú¸éÀû |
72 §³ |
â ¸éÀû : ÁöºØ |
10 §³ |
º® |
36 §³ |
Cost |
¡Ì600,000(1983) |
Thermal |
|
¿°ü·ùÀ² : ÁöºØ |
0.36 W/§³K |
¹Ù´Ú |
0.11 W/§³K |
¿Üº® |
0.34 W/§³K |
â |
2.80 W/§³K |
Æò±Õ¿°ü·ùÀ² |
0.62 W/§³K |
Global heat loss coefficient |
2617 W/K |
ħ±âÀ² |
0.5 ac/h |
¿ÜºÎ¼³°è¿Âµµ |
0 ¡É |
Heated floor area |
1,899 §³ |
Heated volume |
6,085 §© |
Net heat load |
57 kWh/§³ |
Site and climate |
|
Altitude |
75 m |
Latitude |
53°21¡ÇN |
Longitude |
02°16¡ÇW |
Average ambient temp: Jan |
4 ¡É |
July |
15.5 ¡É |
Degree Days (base 18.3¡É) |
3158 |
Global irradiation |
950 kWh/§³ |
Sunshine hours |
1450 hrs |